Back to portfolio / 返回作品集

BMC/IPMI Fault Code Quick Reference & Runbook

BMC/IPMI 故障码速查与手册

Problem / 问题

SEL noise hides the critical events. Presence, boot, and cleared lines bury the one row that should page someone. Triage is tribal knowledge: the same phrase is cooling on a temperature sensor and a rail on a voltage sensor, and the person who knows the difference is not on every shift.

系统事件日志的噪声会把严重事件盖住。在位、启动和已经解除的行,把真正该叫醒人的那一行埋掉。分诊是口头经验:同一句短语在温度上是散热,在电压上是电源轨,而知道差别的人并不是每个班次都在。

Approach / 做法

A code table maps the sensor type and the event phrase to a severity, a category, and a runbook. A deasserted line drops one severity step. The script groups the capture by host and category, prints the runbook path, and exits 2 while any critical row remains. The flowchart below is the same path on paper. Samples are synthetic hosts only.

码表把传感器类型和事件短语对应到严重级别、类别和手册。已解除的行把级别降一档。脚本按主机和类别汇总,打印手册路径,只要还剩严重项就退出码 2。下面的流程图是同一条路径。示例主机都是合成的。

Triage flowchart / 分诊流程

Collect the SEL and SDR, match the phrase, lower a deasserted line, then open the runbook, schedule a window, or record it. Exit 0 when nothing critical remains. Exit 2 when it does.

先收集 SEL 和 SDR,匹配短语,已解除的降一档,然后打开手册、排窗口,或只记录。没有严重项是退出码 0,还有就是 2。

IPMI / BMC fault triage Collect SEL and SDR Parse pipe-delimited rows Match type and event keyword Deasserted? Lower severity one step Keep severity Which severity? Critical: open runbook Warning: schedule window Info: record only Group by host and category Write md, csv, and json reports Any critical left? Exit 0 Exit 2 yes no no yes

Demo output / 演示输出

Stdout of python3 demo.py on the two synthetic hosts. The parser reports 59 findings, 19 critical, and exits 2. The demo process then exits 0.

python3 demo.py 对两台合成主机的标准输出。解析结果是 59 条发现、严重 19 条、退出码 2。演示进程随后以 0 结束。

BMC/IPMI fault code kit demo

$ python3 scripts/ipmi_triage.py --sel samples/srv-a01_sel_elist.txt samples/srv-b02_sel_elist.txt --sdr samples/srv-a01_sdr.txt samples/srv-b02_sdr_elist.txt --out out
findings: 59  critical: 19  warning: 25  info: 15  exit: 2
Host                Category   Severity  Count  Action        Runbook                 
------------------  ---------  --------  -----  ------------  ------------------------
dc1-rack-a01-srv01  battery    warning   2      RB-BATTERY    runbooks/RB-BATTERY.md  
dc1-rack-a01-srv01  battery    info      1      RB-BATTERY    runbooks/RB-BATTERY.md  
dc1-rack-a01-srv01  bmc        critical  1      RB-BMC        runbooks/RB-BMC.md      
dc1-rack-a01-srv01  bmc        info      1      RB-BMC        runbooks/RB-BMC.md      
dc1-rack-a01-srv01  cpu        critical  1      RB-CPU        runbooks/RB-CPU.md      
dc1-rack-a01-srv01  cpu        warning   1      RB-CPU        runbooks/RB-CPU.md      
dc1-rack-a01-srv01  fan        critical  2      RB-FAN        runbooks/RB-FAN.md      
dc1-rack-a01-srv01  fan        warning   2      RB-FAN        runbooks/RB-FAN.md      
dc1-rack-a01-srv01  fan        info      1      RB-FAN        runbooks/RB-FAN.md      
dc1-rack-a01-srv01  intrusion  critical  1      RB-INTRUSION  runbooks/RB-INTRUSION.md
dc1-rack-a01-srv01  memory     critical  1      RB-MEM-ECC    runbooks/RB-MEM-ECC.md  
dc1-rack-a01-srv01  memory     warning   1      RB-MEM-ECC    runbooks/RB-MEM-ECC.md  
dc1-rack-a01-srv01  pcie       critical  1      RB-PCIE       runbooks/RB-PCIE.md     
dc1-rack-a01-srv01  pcie       warning   1      RB-PCIE       runbooks/RB-PCIE.md     
dc1-rack-a01-srv01  power      critical  2      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-a01-srv01  power      warning   3      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-a01-srv01  power      info      2      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-a01-srv01  sel        critical  1      RB-SEL-FULL   runbooks/RB-SEL-FULL.md 
dc1-rack-a01-srv01  sel        warning   1      RB-SEL-FULL   runbooks/RB-SEL-FULL.md 
dc1-rack-a01-srv01  sel        info      1      RB-SEL-FULL   runbooks/RB-SEL-FULL.md 
dc1-rack-a01-srv01  thermal    critical  2      RB-THERMAL    runbooks/RB-THERMAL.md  
dc1-rack-a01-srv01  thermal    warning   4      RB-THERMAL    runbooks/RB-THERMAL.md  
dc1-rack-a01-srv01  thermal    info      1      RB-THERMAL    runbooks/RB-THERMAL.md  
dc1-rack-a01-srv01  unknown    info      1                    -                       
dc1-rack-a01-srv01  watchdog   critical  2      RB-WATCHDOG   runbooks/RB-WATCHDOG.md 
dc1-rack-a01-srv01  watchdog   info      1      RB-WATCHDOG   runbooks/RB-WATCHDOG.md 
dc1-rack-b02-srv02  battery    warning   1      RB-BATTERY    runbooks/RB-BATTERY.md  
dc1-rack-b02-srv02  bmc        warning   1      RB-BMC        runbooks/RB-BMC.md      
dc1-rack-b02-srv02  bmc        info      1      RB-BMC        runbooks/RB-BMC.md      
dc1-rack-b02-srv02  cpu        critical  1      RB-CPU        runbooks/RB-CPU.md      
dc1-rack-b02-srv02  cpu        warning   1      RB-CPU        runbooks/RB-CPU.md      
dc1-rack-b02-srv02  fan        warning   2      RB-FAN        runbooks/RB-FAN.md      
dc1-rack-b02-srv02  memory     info      1      RB-MEM-ECC    runbooks/RB-MEM-ECC.md  
dc1-rack-b02-srv02  pcie       warning   1      RB-PCIE       runbooks/RB-PCIE.md     
dc1-rack-b02-srv02  power      critical  2      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-b02-srv02  power      warning   2      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-b02-srv02  power      info      1      RB-PSU        runbooks/RB-PSU.md      
dc1-rack-b02-srv02  storage    critical  1      RB-STORAGE    runbooks/RB-STORAGE.md  
dc1-rack-b02-srv02  storage    warning   1      RB-STORAGE    runbooks/RB-STORAGE.md  
dc1-rack-b02-srv02  thermal    info      1      RB-THERMAL    runbooks/RB-THERMAL.md  
dc1-rack-b02-srv02  watchdog   critical  1      RB-WATCHDOG   runbooks/RB-WATCHDOG.md 
dc1-rack-b02-srv02  watchdog   warning   1      RB-WATCHDOG   runbooks/RB-WATCHDOG.md 
dc1-rack-b02-srv02  watchdog   info      2      RB-WATCHDOG   runbooks/RB-WATCHDOG.md 
recommended:
- dc1-rack-a01-srv01  bmc  critical  x1
  what: The management controller is off-line
  action: Save the SEL first. Reset the management controller only after the log is stored.
  runbook: runbooks/RB-BMC.md
- dc1-rack-a01-srv01  cpu  critical  x1
  what: The processor reported an internal error
  action: Save the SEL. Treat a repeated IERR, thermal trip, or machine check as a board fault.
  runbook: runbooks/RB-CPU.md
- dc1-rack-a01-srv01  fan  critical  x2
  what: Fan speed crossed the lower critical mark
  action: Confirm the fan is seated and spinning. Swap it if it stays below the low mark.
  runbook: runbooks/RB-FAN.md
- dc1-rack-a01-srv01  intrusion  critical  x1
  what: The chassis was opened
  action: Confirm someone was in the rack, close the chassis, and clear the latch on purpose.
  runbook: runbooks/RB-INTRUSION.md
- dc1-rack-a01-srv01  memory  critical  x1
  what: Memory logged an uncorrectable ECC error
  action: Map the DIMM, reseat once, and replace it if uncorrectable errors return.
  runbook: runbooks/RB-MEM-ECC.md
- dc1-rack-a01-srv01  pcie  critical  x1
  what: A PCI system error was signaled
  action: Note the slot, reseat the card, and move it before calling the board failed.
  runbook: runbooks/RB-PCIE.md
- dc1-rack-a01-srv01  power  critical  x2
  what: A power supply lost AC input
  action: Check the feed, the supply LED, and redundancy before pulling a supply.
  runbook: runbooks/RB-PSU.md
- dc1-rack-a01-srv01  sel  critical  x1
  what: The system event log is full
  action: Export the SEL, store the file, and only then clear the log.
  runbook: runbooks/RB-SEL-FULL.md
- dc1-rack-a01-srv01  thermal  critical  x2
  what: Temperature crossed the upper critical mark
  action: Check inlet temperature, fan speed, and blanking before replacing a heat sink.
  runbook: runbooks/RB-THERMAL.md
- dc1-rack-a01-srv01  watchdog  critical  x2
  what: The watchdog timer expired
  action: Save the console. Reboot only after deciding the OS hung rather than a firmware loop.
  runbook: runbooks/RB-WATCHDOG.md
- dc1-rack-b02-srv02  cpu  critical  x1
  what: The processor shut down on a thermal trip
  action: Save the SEL. Treat a repeated IERR, thermal trip, or machine check as a board fault.
  runbook: runbooks/RB-CPU.md
- dc1-rack-b02-srv02  power  critical  x2
  what: Power redundancy is gone
  action: Check the feed, the supply LED, and redundancy before pulling a supply.
  runbook: runbooks/RB-PSU.md
- dc1-rack-b02-srv02  storage  critical  x1
  what: A drive reported a fault
  action: Name the bay and replace a faulted drive before a second member fails.
  runbook: runbooks/RB-STORAGE.md
- dc1-rack-b02-srv02  watchdog  critical  x1
  what: The watchdog forced a hard reset
  action: Save the console. Reboot only after deciding the OS hung rather than a firmware loop.
  runbook: runbooks/RB-WATCHDOG.md
wrote out/report.md (17187 bytes)
wrote out/report.csv (22882 bytes)
wrote out/report.json (71267 bytes)
triage exit 2
demo complete

Deliverables / 交付物

The free lite repo keeps the parser, a 12-row thermal and power subset, the flowchart, and RB-THERMAL plus RB-PSU. 免费精简仓库保留解析器、十二行温度和电源子集、流程图,以及这两本手册。

Delivery time / 交付时间

Instant download. Setup about 5 minutes. Adapting the code table and runbooks to your fleet about 30 minutes.

下载即得。安装并跑通大约 5 分钟。把码表和手册改成你的机器大约 30 分钟。

Pay what you want, $1 or more. Suggested price is $5. 愿付多少付多少,1 美元起,建议 5 美元。